法拉第旋转器一种磁光装置,光在处于磁场中的透明介质中传播。磁场方向与光束传播方向相同或者相反。如果光是某一方向的线偏振光,那么光通过介质时偏振方向不断的发生变化。总的旋转角为β : β =V B L 其中V是材料的维尔德常数,B为磁通量(传播方向上的),L是介质的长度。维尔德常数是与波长密切相关的,波长越长,常数越小。 偏振方向的变化只与磁场方向和维尔德常数的符号有关。如果线偏振光先通过法拉第旋转器,经过反射镜后又重新通过法拉第旋转器,那么旋转角度为单次通过时旋转角的二倍,而不是相互抵消。这一非互易性质使法拉第旋转器与波片和偏振器区别开来。 要理解偏振态旋转的物理意义,可以将线偏振光看成两个圆偏振光的叠加。磁场使两圆偏振光产生相速度差。而相对相移则对应于线偏振光方向的变化。
Definition: devices which can rotate the polarization state of light, exploiting the Faraday effect
A Faraday rotator is a magneto-optic device, where light is transmitted through a transparent medium which is exposed to a magnetic field. The magnetic field lines have approximately the same direction as the beam direction, or the opposite direction. If the light is linearly polarized in some direction, this polarization direction is continuously rotated during the passage through the medium. The total rotation angle β can be calculated as
where V is the Verdet constant of the material, B is the magnetic flux density (in the direction of propagation), and L is the length of the rotator medium. Note that the Verdet “constant” usually exhibits a substantial wavelength dependence: it is smaller for longer wavelengths.
An important aspect is that the change of polarization direction is defined only by the magnetic field direction and the sign of the Verdet constant. If some linearly polarized beam is sent through a Faraday rotator and back again after reflection at a mirror, the polarization changes of the two passes add up, rather than canceling each other. This non-reciprocal behavior distinguishes Faraday rotators e.g. from arrangements of waveplates and polarizers.
Concerning the physical origin of the polarization rotation, one may consider a linearly polarized beam as a superposition of two circularly polarized beams. The magnetic field causes a difference in phase velocity between these circularly polarized components. The resulting relative phase shift corresponds to a change in the linear polarization direction.
Construction Details
The magnetic field is usually generated with an assembly of permanent magnets and ferromagnetic materials, which is optimized such that the following goals are more or less achieved:
The field strength should be as high as possible, such that a certain rotation angle (e.g. 45°) can be achieved with a short rotator medium. This reduces detrimental effects related to parasitic absorption (and the resulting thermal effects) and to nonlinearities of the medium.
The magnetic flux density should be as uniform as possible over the region where light is sent through the medium. In that way, a spatially uniform rotation angle is achieved.
These goals involve certain design trade-offs. In particular, a larger geometric cross section with good field homogeneity tends to require stronger magnets or to reduce the achievable field strength. For such reasons, devices are optimized for different purposes. There are heavy and expensive high-power devices with a large aperture as well as much cheaper miniature devices for low power levels.
Apart from a high Verdet constant, the Faraday medium should exhibit a high transparency in the spectral region of interest, a high optical quality, and sometimes also a high optical damage threshold. Often used Faraday media for the near-infrared spectral region are terbium–gallium garnet crystals (TGG) and terbium-doped borosilicate glass, which exhibit relatively large Verdet constants. A common choice for telecom components operating in the 1.3-μm or 1.5-μm spectral region is yttrium iron garnet (YIG).
For operation with high optical average powers, parasitic absorption in a Faraday rotator can lead to substantial internal heating and consequently to thermal beam distortions. In particular, thermal lensing can occur. Both the power-dependence and the significant optical aberrations of the thermal lens can be very disturbing. Additional aspects of high-power operation are discussed in the article on Faraday isolators.
In most cases, reflection losses on the input and output surface of a Faraday rotator are minimized with anti-reflection coatings, designed for the intended range of operation wavelengths. Note that the operation bandwidth can be limited not only by the coatings, but also by the wavelength dependence of the Verdet constant.
Applications
Faraday rotators find many applications in laser technology:
A particularly important application is in Faraday isolators, as needed e.g. to protect lasers and amplifiers against back-reflected light. For that application, the rotation angle should be close to 45° in the spectral region of interest. A highly uniform polarization rotation is desirable for obtaining a large attenuation for back-reflected light.
A Faraday rotator in a ring laser resonator can be used to introduce round-trip losses which depend on the direction and thus enforce unidirectional operation. As only a very small loss difference is often sufficient, a Faraday rotator providing only a very small rotation angle may be sufficient. An additional half-waveplate may be used to compensate the polarization rotation for one beam direction.
Figure 1: Setup of a double-pass laser amplifier. The Faraday mirror on the right side ensures that the polarization state of light is not distorted after a double pass through the amplifier medium.
A 45° rotator combined with an end mirror forms a Faraday mirror. If a laser beam is sent through some amplifier (see Figure 1), then reflected at such a Faraday mirror and sent back through the amplifier, the returning beam has a polarization direction which is orthogonal to that of the input beam – even if the polarization state is not preserved within the amplifier. Therefore, a polarizer can reliably separate the counterpropagating beams. This works better than using a Faraday isolator (with an output port for reflected light), an amplifier and an ordinary mirror.
The latter technique can also be utilized in similar form within laser resonators of certain high-power lasers for minimizing the polarization distortions and thus depolarization loss.
Fiber-coupled Faraday mirrors are useful e.g. in fiber-optic interferometers and certain fiber lasers.
A variant of isolators are Faraday circulators, having three optical ports.